Ignore:
Timestamp:
09/28/2011 09:34:55 PM (20 months ago)
Author:
dschultzca
Message:

LM-2 MTS refactoring, almost complete and is in a working state. Also added GaugeMinMax? to External sensors but the values chossen may not be optimal.
Bumping up to 0.5.4Beta due to the extent of the changes to the logger.
COM4J upgrade to version released 20110322.

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/release_notes.txt

    r344 r348  
    1                     - RomRaider 0.5.3 Beta RC10 - 
     1                    - RomRaider 0.5.4 Beta RC1 - 
    22            Open-Source ECU Tuning -- www.romraider.com 
    33 
     
    88 
    99RomRaider is a full featured Engine Control Unit editing application 
    10 for tuning virtually any manufacturer, meant to be used in conjuction 
     10for tuning virtually any manufacturer, meant to be used in conjunction 
    1111with ECU flash and dump utilities. RomRaider will give you full 
    1212control over timing, fuel, boost and many other parameters in your 
     
    3434 
    3535 
    36 ------------------------------- 
    37 - 0.5.3b RC11 Notes (??/??/????) - 
    38 ------------------------------- 
     36--------------------------------- 
     37- 0.5.4b RC1 Notes (??/??/????) - 
     38--------------------------------- 
    3939This is the eleventh beta release of the upcoming official 0.5.3b release. 
    4040 
    4141--------------------------- 
    42 - 0.5.3b RC11 Known Issues - 
     42- 0.5.4b RC1 Known Issues - 
    4343--------------------------- 
    4444- Editor 
    4545  - Pasting table data can cause hangs under certain circumstances 
    4646- Logger 
    47   - Gauge min/max/step limits incomplete (logger.xml) 
     47  - Gauge min/max/step limits incomplete in logger.xml and External plug-ins 
    4848  - ECU connections under Linux are flaky (start the logger after 
    4949      you've started the engine) 
    5050  - Update latency via injector tab broken for some models (eg. 2007 2.5i) 
    51   - LM-2 MTS support incomplete 
    5251 
    5352 
     
    5655-------------- 
    5756 
    58 0.5.3b RC11 (??/??/????) 
     570.5.4b RC1 (??/??/????) 
    5958----------------------- 
    6059 
     
    6665- Added support for convertors on External data items (F/C, lambda/AFR, etc.) 
    6766- Added all defined PLX Sensors according to their documentation 
    68   
     67- Added more Innovate MTS LM-2 support for additional sensors.  Sensors are now 
     68  loaded dynamically when the Logger starts.  Sensor units are set via LogWorks. 
     69- Updated library COM4J to version: com4j-20110322. This affects Innovate MTS 
     70  and Tactrix Openport 2.0 support. 
     71--- Editor --- 
     72- Fixed JInternalFrame.isPalette in TableFarme so table titles are visible on 
     73  Mac OS. 
     74   
     75 
    69760.5.3b RC10 (09/12/2011) 
    70 ----------------------- 
     77------------------------ 
    7178 
    7279--- Editor --- 
    7380- Added support for multiple-state switches.  Switch Tables will now use 
    7481  Radio Buttons rather than a Checkbox. 
    75 - Added ECU defintion data validation for Switch Tables.  If the ROM image data 
     82- Added ECU definition data validation for Switch Tables.  If the ROM image data 
    7683  does not match one of the switch states according to the definition then a 
    7784  warning is presented and the table is locked from editing. 
Note: See TracChangeset for help on using the changeset viewer.